3.0 SETTING UP THE TCAT-2AC CONTROLLER
3.1 Connect a suitable load (500 Watts maximum) to either of the auxiliary AC outlets on the rear
panel of the TCAT-2AC using the auxiliary AC adaptor cable if necessary.
3.2 Insert a type T thermocouple feedback sensor into the blue socket. Ensure that the sensor tip is
securely attached to the load at an appropriate location. Call our Engineering Applications Department
(1-800-452-8510) for more information on sensor placement.
3.3 Connect the AC power cord to the AC input module and to any suitable AC outlet.
3
POWER
SWITCH
AC FUSE
REPLACE WITH
......ONLY
AUXILIARY AC OUTPUTSOCKETS
THERMOCOUPLE SOCKET
FOR FEEDBACK SENSOR
REAR PANEL CONNECTIONS
Vedere la pagina 7